Unshielded - Double insulated PVC single conductor
Applicazione
these cables are ideally suited for use in drag chains, and also for use in handling devices, robots, and nearly any area requiring flexible used and free motion.
Costruzione
Bare copper, extra fine wire conductor to DIN VDE 0295 cl. 6 and IEC 60228 cl. 6;
PVC insulation, green-yellow;
PVC jacket compound TM2;
Jacket color gray.
Campo di temperatura: flexing -5°C to +80°C;fixed installation -40°C to +80°C
Tensione nominale:U0/U 600/1000 V
A.C. tensione di prova, 50 Hz: 3000 V
Raggio minimo di curvatura: for flexible installation; approx. 5x cable Ø
Resistenza di isolamento: min. 20 MOhm x km
Proprietà
PVC self-extinguishing and flame retardant according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1
(equivalent DIN VDE 0472 part 804 test method B);
Chemical resistance see table Technical Information;
Unshielded - Double insulated,PVC single conductor.
Unshielded - Double insulated, PVC single conductor
Conductors x cross-sec. mm² |
Outer
Diameter |
Copper weight
kg/km |
Weight
ca. kg/km |
AWG |
1x2.5 |
4.5 |
24.0 |
42.0 |
14 |
1x4 |
5.6 |
38.4 |
58.0 |
12 |
1x6 |
6.1 |
57.6 |
85.0 |
10 |
1x10 |
8.0 |
96.0 |
130.0 |
8 |
1x16 |
9.8 |
154.0 |
190.0 |
6 |
1x25 |
11.8 |
240.0 |
280.0 |
4 |
1x35 |
12.9 |
336.0 |
400.0 |
2 |
1x50 |
14.6 |
480.0 |
520.0 |
1 |
1x70 |
17.5 |
672.0 |
720.0 |
2/0 |
1x95 |
20.0 |
912.0 |
1050.0 |
3/0 |
1x120 |
21.6 |
1152.0 |
1220.0 |
4/0 |
1x150 |
23.5 |
1440.0 |
1500.0 |
300 kcmil |
1x185 |
25.7 |
1776.0 |
1940.0 |
350 kcmil |
1x240 |
29.5 |
2304.0 |
1675.0 |
500 kcmil |
1x300 |
32.5 |
2880.0 |
3300.0 |